Research & Technical Library

Process technology

Analysis and concentration control plan for PPS pretreatment baths

Overview

We reviewed wet chemical analysis methods and concentration and contamination control items for PPS pretreatment baths.

To manage PPS pretreatment bath concentrations on site, we reviewed analytical methods for degreasing, etching, cleaning and conditioning. We examined titration and specific gravity methods suited to the available equipment, and documented measurement interferences and calibration conditions.

We defined separate control items for chemical concentration checks and for assessing bath contamination and service life.

AttachmentAnalysis and concentration control plan for PPS pretreatment baths.docx
Back to list