Overview
We reviewed wet chemical analysis methods and concentration and contamination control items for PPS pretreatment baths.
To manage PPS pretreatment bath concentrations on site, we reviewed analytical methods for degreasing, etching, cleaning and conditioning. We examined titration and specific gravity methods suited to the available equipment, and documented measurement interferences and calibration conditions.
We defined separate control items for chemical concentration checks and for assessing bath contamination and service life.